Impacta 300Hybrid PABX

  • Description

    Cores: 
     

    Hybrid PABX of greatest capacity of the Impacta line. Ideal for companies which require converging solutions in telephony. A means of communication which adds  technologies TDM, IP and GSM in the same platform, allowing greatly reduced costs (by using automatic output routing) and the possibility of interlinking of parent company and branches through IP communication. Available for assembly in 19” rack.

     

    Check the availability of this product in your country.

  • Technical Specifications

    Não foi possível localizar uma resposta para sua busca.

  • Step by step configuration

    Não foi possível localizar uma resposta para sua busca.

  • Downloads

    Não foi possível localizar uma resposta para sua busca.

  • FAQ

    Product Features
    1 - How many extension line groups can I have in the Impacta 300 switch?

    In the Impacta 300 switch it is possible to create 20 extension line Groups. 

    In the Impacta 300 switch it is possible to create 20 extension line Groups. 

    2 - How many Tickets are stored in the switch?

    The Impacta switches can store up to 905 tickets. 

    The Impacta switches can store up to 905 tickets. 

    3 - How many analog lines can I connect in the Impacta 300 switch?

    It is possible to install up to 24 analog lines in the Impacta 300 switch *.

    * the total quantity of analog lines is limited to the number of slots free in the switch. For further information see the programming software. 

    It is possible to install up to 24 analog lines in the Impacta 300 switch *.

    * the total quantity of analog lines is limited to the number of slots free in the switch. For further information see the programming software. 

    4 - How many account codes can I have in the Impacta 300 switch?

    It is possible to program up to 300 account codes.

    It is possible to program up to 300 account codes.

    5 - What is the power of the Impacta 300 switch?

    The maximum power of Impacta 300 is 210W.

    The maximum power of Impacta 300 is 210W.

    Pages

    Installation
    1 - How many intelligent terminals can I connect in my Impacta 300 switch?

    It is possible to connect up to 48 Intelligent Terminals TI 4245i per switch. And for each key module added, we eliminate an intelligent terminal position.

    It is possible to connect up to 48 Intelligent Terminals TI 4245i per switch. And for each key module added, we eliminate an intelligent terminal position.

    2 - At what distance can the Analog Line be installed?

    The distance of the line is not specified in meters. One must consider the impedance of the line, which must not exceed 2000 Ohms.

    The distance of the line is not specified in meters. One must consider the impedance of the line, which must not exceed 2000 Ohms.

    Basic Settings
    1 - What do I do to hear the number of my Extension Line?

    To hear the extension line number, press *  87 *. 

    To hear the extension line number, press *  87 *.

    2 - Extension lines without call ID.

    The switch has a call identifier for all the telephone lines without requiring any other accessory.

    Nevertheless, it is necessary to program the lines and extension lines of the switch, enable the function altering the jumper in the trunk board (J3A up to J3H and J4A up to J4H) and contract the service with the telephone company.

    Configuration of jumper: J3 (A a H) position 2-3 and J4 (A to H) position 1-2 configured for call ID.

    Boards: 3250461/1 and 3250461/2

     

    New boards and board 2 junctors and 12 extension lines: as of 3250461/3.

    Configuration of jumper: J3 (A to H) and J4 (A to H) configured in position 2-3 for call ID. 

    The switch has a call identifier for all the telephone lines without requiring any other accessory.

    Nevertheless, it is necessary to program the lines and extension lines of the switch, enable the function altering the jumper in the trunk board (J3A up to J3H and J4A up to J4H) and contract the service with the telephone company.

    Configuration of jumper: J3 (A a H) position 2-3 and J4 (A to H) position 1-2 configured for call ID.

    Boards: 3250461/1 and 3250461/2

     

    New boards and board 2 junctors and 12 extension lines: as of 3250461/3.

    Configuration of jumper: J3 (A to H) and J4 (A to H) configured in position 2-3 for call ID. 

     

     

     

    Problem Solutions
    1 - Link E1 does not synchronize.

    Check the sheathing jumpers in board of E1 (Maintain the two jumpers of the link closed for TEST). The flat cable must be well connected. If possible do a test with another cable.

    Make a loop between TX and RX of the link with a metallic wire. Aligning with the metallic wire, execute the loop test with the coaxial cable and if it does not align, replace the cable.

    If your board is R2 Digital, forward the Firmware corresponding to the signaling type.

    The firmware must be sent through the Web programmer in option Maintenance > Recording - Send > Choose the option "Firmware (Boot E1)" and Select file "Firmware_E1_R2_Brasil". 

    Check the sheathing jumpers in board of E1 (Maintain the two jumpers of the link closed for TEST). The flat cable must be well connected. If possible do a test with another cable.

    Make a loop between TX and RX of the link with a metallic wire. Aligning with the metallic wire, execute the loop test with the coaxial cable and if it does not align, replace the cable.

    If your board is R2 Digital, forward the Firmware corresponding to the signaling type.

    The firmware must be sent through the Web programmer in option Maintenance > Recording - Send > Choose the option "Firmware (Boot E1)" and Select file "Firmware_E1_R2_Brasil".