Modulare iAnalog PABX

  • Description

    Cores: 
     

    The analog PABX Modulare i can be used in the corporate environment, as it offers simple configuration and operation, reduced costs through automatic line selection and total integration with access control and automation. Choose the best-selling PABX in Latin America.

     

    Check the availability of this product in your country.

  • Technical Specifications

    Não foi possível localizar uma resposta para sua busca.

  • Step by step configuration

    Não foi possível localizar uma resposta para sua busca.

  • Downloads

    Não foi possível localizar uma resposta para sua busca.

  • FAQ

    Product Features
    1 - What is the maximum time for the automatic answering message (DISA)?

    It is possible to record a local message of up to 15seconds.  The personalized messages Day and Night also have the maximum capacity of up to 15seconds. 

    It is possible to record a local message of up to 15seconds.  The personalized messages Day and Night also have the maximum capacity of up to 15seconds. 

    2 - How many Tickets are stored in the switch?

    The switch can store up to 600 Tickets. 

    The switch can store up to 600 Tickets. 

    3 - How many people can listen to the automatic answering message (DISA) at the same time?

    Conecta and Modulare i - Only one call at a time will be able to handle the automatic answering  message.
    Corps and digital - Check the model of the DISA board installed in the switch. There are two models.
    Disa 1 channel board: Only one call at a time will be able to handle the automatic answering  message. Disa 2 channels board: Two simultaneous calls  time will be able to handle the automatic answering  message. 

    Conecta and Modulare i - Only one call at a time will be able to handle the automatic answering  message.
    Corps and digital - Check the model of the DISA board installed in the switch. There are two models.
    Disa 1 channel board: Only one call at a time will be able to handle the automatic answering  message. Disa 2 channels board: Two simultaneous calls  time will be able to handle the automatic answering  message. 

    4 - What is the power of Switch Modulare I?

    The power of the switch is 24W. 

    The power of the switch is 24W. 

    Installation
    1 - At what distance can the Analog Line be installed?

    The distance of the line is not indicated in meters. One must measure the impedance of the line, which must not exceed 2000 Ohms. 

    The distance of the line is not indicated in meters. One must measure the impedance of the line, which must not exceed 2000 Ohms. 

    2 - What is the maximum distance at which I can install my analog extension line?

    The distance of the extension line is not indicated in meters. One must measure the impedance of the extension line including the telephone appliance and this impedance must not exceed 1100 Ohms. 

    The distance of the extension line is not indicated in meters. One must measure the impedance of the extension line including the telephone appliance and this impedance must not exceed 1100 Ohms. 

    3 - How many extension lines can I connect in switch Modulare I?

    The switch has the maximum capacity of 8 Extension Lines. 

    The switch has the maximum capacity of 8 Extension Lines. 

    4 - What is the maximum capacity of analog lines of switch Modulare I?

    It is possible to install up to 4 analog lines* in switch Modulare I.

    * In order to install lines 3 and 4 you will need to acquire a trunk board for line 3 and another one for line 4. 

    It is possible to install up to 4 analog lines* in switch Modulare I.

    * In order to install lines 3 and 4 you will need to acquire a trunk board for line 3 and another one for line 4. 

    5 - How many intelligent Terminals can I connect in switch Modulare I/Conecta?

    It is possible to connect up to 3 intelligent terminals in switch Modulare I/Conecta.

    It is possible to connect up to 3 intelligent terminals in switch Modulare I/Conecta.

    Pages

    Problem Solutions
    1 - Extension line cannot transfer calls received. My extension line does not transfer calls received.

    Program the flash time in the switch extension lines. In the extension line which does not transfer calls key command 165 + 9 and wait for the accept programming tone.

    Also check that the extension line which shall receive the call has a category to receive external calls. Lastly, make a  test altering the music jumper to external music. 

    Program the flash time in the switch extension lines. In the extension line which does not transfer calls key command 165 + 9 and wait for the accept programming tone.

    Also check that the extension line which shall receive the call has a category to receive external calls. Lastly, make a  test altering the music jumper to external music. 

    2 - Extension line without music in transfer of calls.

    Check if the jumper which enables the internal music, jumper J9 , is closed.

    If you use external music for the transfer, check if the cable is monochannel and if it is well connected at  output Mus EXT. Bearing in mind that for external music jumper J9 must be open.

    Check if the jumper which enables the internal music, jumper J9 , is closed.

    If you use external music for the transfer, check if the cable is monochannel and if it is well connected at  output Mus EXT. Bearing in mind that for external music jumper J9 must be open.

    3 - Extension lines without call ID . My extension lines do not identify the calls.

    First, ensure that the telephone line has the call ID service enabled.  Then check if the switch is equipped with the call ID board (IDA). Alter the ID jumpers to position IC. Execute the programming of the switch to enable the ID of the calls. 

    First, ensure that the telephone line has the call ID service enabled.  Then check if the switch is equipped with the call ID board (IDA). Alter the ID jumpers to position IC. Execute the programming of the switch to enable the ID of the calls.